COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 5 PICK UP/FEEDING SYSTEM5-79 P3) Remove the two mounting screws [4],and detach the duplex feeding fan [5].Be sure that the arrow indicat-ing the direction of air is as in-dicated when mounting the du-plex feeldng fan.F05-906-279.6.17 Mounting the Reversing Flapper Solenoid1) Adjust the position of the solenoid us-ing two screws [2] so that the drive le-ver [1] is fully pushed when the sole-noid turns on (i.e., the plunger isdrawn).F05-906-28[5][4][1][2]