1094 | Uplink Failure Detection (UFD)w w w . d e l l . c o m | s u p p o r t . d e l l . c o m Figure 54-4. show interfaces Command: UFD OutputFigure 54-5. show running-config uplink-state-group Command: UFD OutputFigure 54-6. show configuration Command: UFD OutputFTOS#show interfaces gigabitethernet 7/45GigabitEthernet 7/45 is up, line protocol is down (error-disabled[UFD])Hardware is Force10Eth, address is 00:01:e8:32:7a:47Current address is 00:01:e8:32:7a:47Interface index is 280544512Internet address is not setMTU 1554 bytes, IP MTU 1500 bytesLineSpeed 1000 Mbit, Mode autoFlowcontrol rx off tx offARP type: ARPA, ARP Timeout 04:00:00Last clearing of "show interface" counters 00:25:46Queueing strategy: fifoInput Statistics:0 packets, 0 bytes0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts0 Multicasts, 0 Broadcasts0 runts, 0 giants, 0 throttles0 CRC, 0 overrun, 0 discardedOutput Statistics:0 packets, 0 bytes, 0 underruns0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts0 Multicasts, 0 Broadcasts, 0 Unicasts0 throttles, 0 discarded, 0 collisionsRate info (interval 299 seconds):Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rateOutput 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rateTime since last interface status change: 00:01:23FTOS#show running-config uplink-state-group!no enableuplink state track 1downstream GigabitEthernet 0/2, 4, 6, 11-19upstream TengigabitEthernet 0/48, 52upstream PortChannel 1!uplink state track 2downstream GigabitEthernet 0/1, 3, 5, 7-10upstream TengigabitEthernet 0/56, 60FTOS(conf-uplink-state-group-16)# show configuration!uplink-state-group 16no enabledescription testdownstream disable links alldownstream GigabitEthernet 0/40upstream GigabitEthernet 0/41upstream Port-channel 8