34 BigIron RX Series Configuration Guide53-1001986-01Monitoring management module redundancy3 SoftwareTo display the status of the management modules, enter the following command at any CLI level.Syntax: show moduleThe Status column indicates the module status. The management modules can have one of thefollowing status:• ACTIVE – The module is currently the active management module.• STANDBY – The module is the standby management module. The status of the standby modulecan be one of the following:• Init – The module is currently initializing as the standby module.• Ready – The module is ready to take over as the active module, if necessary.• Wait – The module is awaiting boot information from the active management module.• Sync – The active module is currently synchronizing files between itself and the standbymodule.Displaying temperature informationEach management module contains a temperature sensor. By default, the BigIron RX system pollsthe temperature of each management module every 60 seconds. You can display the currenttemperature of the management modules (and all other modules) by entering the followingcommand at any CLI level.Syntax: show chassisThe output displays the temperature of the management modules in the BigIron RX chassis andalso indicates that the temperature readings were provided within the last 60 seconds.Displaying switchover informationYou can display the following related to a switchover:• Redundancy parameter settings and statistics, which include the number of switchover thathave occurred.• System log or the traps logged on an SNMP trap receiver, which includes Information aboutwhether a switchover has occurred.BigIron RX# show moduleModule Status Ports Starting MACM1 (upper): BigIron BI-RX Management Module ActiveM2 (lower): BigIron BI-RX Management Module Standby (Ready)...BigIron RX# show chassis...Active Mgmt Module: 28.43C 57.500C (CPU)Standby Mgmt Module: 29.15C 57.500C (CPU)...Temperature Monitoring Poll Period is 60 seconds...