BigIron RX Series Configuration Guide 127153-1001986-01Syslog messages ASyslog messagesTable 224 lists all of the Syslog messages. The messages are listed by message level, in thefollowing order:• Emergencies (none)• Alerts• Critical• Errors• Warnings• Notifications• Informational• DebuggingTABLE 224 Brocade Syslog messagesMessage level Message ExplanationAlert Power supply , , failed A power supply has failed.The is the power supply number.The describes where the failedpower supply is in the chassis.Alert Fan , , failed A fan has failed.The is the power supply number.The describes where the failedpower supply is in the chassis.Alert Management module at slot state changed from to.Indicates a state change in a managementmodule.The indicates the chassis slotcontaining the module.The can be one of thefollowing:• active• standby• crashed• coming-up• unknownAlert Temperature C degrees, warninglevel C degrees, shutdownlevel C degreesIndicates an overtemperature condition onthe active module.The value indicates thetemperature of the module.The value is the warningthreshold temperature configured for themodule.The value is theshutdown temperature configured for themodule.Alert modules and 1 powersupply, need more power supply!!Indicates that the chassis needs more powersupplies to run the modules in the chassis.The parameter indicates thenumber of modules in the chassis.Alert OSPF Memory Overflow OSPF has run out of memory.