BigIron RX Series Configuration Guide 126753-1001986-01Configuring the Syslog service ADisabling or re-enabling SyslogSyslog is enabled by default. To disable it, enter the following command at the global CONFIG level.BigIron RX(config)# no logging onSyntax: [no] logging on []The parameter specifies the application port used for the Syslog facility. The default is514.To re-enable logging, enter the following command.BigIron RX(config)# logging onThis command enables local Syslog logging with the following defaults:• Messages of all severity levels (Emergencies – Debugging) are logged.• Up to 50 messages are retained in the local Syslog buffer.• No Syslog server is specified.Specifying a Syslog serverTo specify a Syslog server, enter a command such as the following.BigIron RX(config)# logging host 10.0.0.99For backward compatibility, the software reads the old command syntax from the startupconfiguration, and converts it to the new command syntax in the running configuration.Syntax: logging host | <server-name>Specifying an additional Syslog serverTo specify an additional Syslog server, enter the logging host command again, as in thefollowing example. You can specify up to six Syslog servers.Enter a command such as the following.BigIron RX(config)# logging host 10.0.0.99BigIron RX(config)# show logSyslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)Buffer logging: level ACDMEINW, 38 messages loggedlevel code: A=alert C=critical D=debugging M=emergency E=errorI=informational N=notification W=warningStatic Log Buffer:Dynamic Log Buffer (50 entries):21d07h02m40s:warning:list 101 denied tcp 209.157.22.191(0)(Ethernet 4/180010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)19d07h03m30s:warning:list 101 denied tcp 209.157.22.26(0)(Ethernet 4/180010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)17d06h58m30s:warning:list 101 denied tcp 209.157.22.198(0)(Ethernet 4/180010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)