7-15On-screen error message Cause Action0232 Extend RAM Failed ataddress lineDIMM is faulty. • Replace DIMM.• Replace the CPU moduleboard.0233 Memory type mixingdetectedDIMMs of the different typesare installed.Replace DIMM withappropriate one.0234 Single - bit ECC error DIMM is faulty. • Replace DIMM.• Replace the CPU moduleboard.0235 Multiple - bit ECC error DIMM is faulty. • Replace DIMM.• Replace the CPU moduleboard.0250 System battery is dead-Replace and runSETUPNvRAM battery is dead. Replace the CPU moduleboard.0251 System CMOSchecksum bad-Defaultconfiguration usedNvRAM is faulty. • Re-configure using theSetup menu.• Replace the PCI moduleboard.0252 Password checksum bad-Password clearedNvRAM is faulty. • Re-set the password inthe Setup menu.• Replace the PCI moduleboard.0260 System timer error PCI module board is faulty. Replace the PCI moduleboard.0270 Real time clock error RTC is faulty. Replace the PCI moduleboard.0271 Check date and timesettingDate and time of RTC areincorrectly set.• Set the correct date andtime in Setup menu.• Replace the PCI moduleboard.0280 Previous boot incomplete-Default configurationusedConfiguration error in Setupmenu.Check configuration in Setupmenu.02B0 Diskette drive A error Floppy drive A is faulty. Replace the floppy disk driveA.02B2 Incorrect Drive A type -run SETUPConfiguration error in Setupmenu.Specify the correct drive typein Setup menu.02D0 System cache error -Cache disabled• CPU is faulty.• CPU module board isfaulty.• Replace the CPU.• Replace the CPU moduleboard.0B1B PCI System Error onBus/Device/FunctionPCI device is faulty.0B1C PCI Parity Error onBus/Device/FunctionPCI device is faulty.• Replace the PCI deviceboard.• Re-install the PCI deviceboard.• Re-configure the PCIboard.0B22 CPUs are installed out oforderCPU is faulty. Replace the CPU.0B28 Unsupported Processordetected on Processor 1The processor (CPU) notsupported by this server isinstalled in Processor 1.Install the CPU appropriate tothe server.