414 MaintenanceCommand DescriptionpnewThe pnew command has no parameter(s).Patch DirectoriesThere are two patch directories on an IP trunk card:1. /C:/u/patchThis is the default directory for patch files. Patch files should be copiedto this directory.2. /C:/u/patch/retenUse this directory to store patch retention control files. Do not use thisdirectory to store patches and do not remove files from this directory.Flash storage upgradesThese are provided through standard 5 Volt ATA-compatible PC Cards.When installed in an IP trunk card ("hot installation" allowed), the additionalstorage provided by the IP trunk card is made available as A:/.Software upgrade mechanismsUse TM 3.1 to upgrade software. Reboot the IP trunk card to run the newsoftware.Upgrade software using TM 3.1The new IP Trunk 3.01 (and later) software application can be downloadedfrom the TM 3.1 PC to the IP trunk card. Follow the steps in Procedure 69"Upgrading software using TM 3.1" (page 414) to upgrade software.Procedure 69Upgrading software using TM 3.1Step Action1 Download the latest IP Trunk 3.01 (and later) software version fromNortel. Determine the location on the TM 3.1 PC hard drive where itis to be loaded. Record the TM 3.1 PC hard drive location for uselater in this procedure. For more detailed instructions on how toaccess the latest software version, turn to "Check and download IPtrunk card software in TM 3.1" (page 272).2 Open TM 3.1 and launch the ITG ISDN IP Trunks application.3 Check the current software version of the IP trunk cards to beupgraded. To check the software version, double-click a card andNortel Communication Server 1000IP Trunk FundamentalsNN43001-563 02.01 StandardRelease 5.5 21 December 2007Copyright © 2007, Nortel Networks.