CHAPTER 2. MMC ProgrammingSamsung Business Communications 2-161(continued)Timer Name Default Range Unit DescriptionFIRST DIGIT TIME 10 1-250 SEC This timer controls how long the system willwait for dialling to begin before dropping thedial tone and returning the you to error tone.HOK FLASH MAX TM 120 20-2500MSECThis timer monitors the duration of a hook-switch flash to ensure that the flash is validand not a line noise or an accidentalhookswitch bounce LONGEST duration.HOK FLASH MIN TM 70 20-2500MSECThis timer monitors the duration of a hook-switch flash to ensure that the flash is validand not a line noise or an accidental hook-switch bounce SHORTEST duration.HOOK OFF TIME 100 20-2500MSECThis timer controls the time before dial tone issent to a single line station.HOOK ON TIME 200 20-2500MSECThis timer sets the minimum amount of time thatthe system will recognize as an SLT hang up.INQUIRY RELEASE 30 1-250 SEC This timer monitors the duration of theinteraction of the Soft button to determinewhen to return the LCD back to a normalstatus. This timer affects only display phones.INTER DIGIT TIME 10 1-250 SEC This timer controls the grace period betweendialling valid digits before dropping the calland returning you back to error tone.ISDN INT DGT TM 7 1-15 SEC This timer controls the grace period betweendialling valid digits and the end of the diallingstring on an ISDN call.KMMC LOCK OUT TM 30 10-50 SEC This timer controls the grace period betweenprogramming actions while in a programmingsession. The timer automatically returns thesystem to secure programming status.LCR ADVANCE TIME 5 1-250 SEC This timer controls the time before selectingthe next allowable route when a station isallowed to route advance.LCR INTER DIGIT 5 1-250 SEC This timer controls the grace period betweendialling valid digits before accessing a trunk.LONG KEY DETECT 600 0-2500MSECThis timer controls the time a key must be helddown before the key press is repeated.LONG KEY REPEAT 300 0-2500MSECThis timer controls the time between repeateddigits on a long key press.MCL DELAY TIME 4 0-9 SEC This timer controls the time when the systemshould start transmitting Authorisation Codeafter sending MCL access code(Cable&Wireless 131 access). Available in UK only.