B.3 Parameter Table482 YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual H: Multi-Function TerminalsH parameters assign functions to the multi-function input and output terminals. H1: Multi-Function Digital InputsF7-73(78DH) PZD4 Read Sets MEMOBUS/Modbus address for PZD4 Read (PPO Read).Values 0 disable the PZD4 Read.Default: 0Min: 0Max: FFFF–F7-74(78EH) PZD5 Read Sets MEMOBUS/Modbus address for PZD5 Read (PPO Read).Values 0 disable the PZD5 Read.Default: 0Min: 0Max: FFFF–F7-75(78FH) PZD6 Read Sets MEMOBUS/Modbus address for PZD6 Read (PPO Read).Values 0 disable the PZD6 Read.Default: 0Min: 0Max: FFFF–F7-76(790H) PZD7 Read Sets MEMOBUS/Modbus address for PZD7 Read (PPO Read).Values 0 disable the PZD7 Read.Default: 0Min: 0Max: FFFF–F7-77(791H) PZD8 Read Sets MEMOBUS/Modbus address for PZD8 Read (PPO Read).Values 0 disable the PZD8 Read.Default: 0Min: 0Max: FFFF–F7-78(792H) PZD9 Read Sets MEMOBUS/Modbus address for PZD9 Read (PPO Read).Values 0 disable the PZD9 Read.Default: 0Min: 0Max: FFFF–F7-79(793H) PZD10 Read Sets MEMOBUS/Modbus address for PZD10 Read (PPO Read).Values 0 disable the PZD10 Read.Default: 0Min: 0Max: FFFF–<44> Cycle power for setting changes to take effect.<45> If F7-13 is set to 0, then all IP Addresses (as defined with parameters F7-01 to F7-04) must be unique.<46> Set F7-01 to F7-12 when F7-13 is set to 0.<47> Set F7-15 when F7-14 is set to 0 or 2.No.(Addr.) Name Description Setting PageH1-01(438H)<31> Value in parenthesis is the default setting when a 3-wire initialization is performed (A1-03 = 3330).Multi-Function Digital InputTerminal S1 Function SelectionAssigns a function to the multi-function digital inputs.Refer to H1 Multi-Function Digital Input Selections on page 483 for a description of settingvalues.Note: Unused terminals should be set to F.Default: 40 (F) <31>Min: 1Max: 9F235H1-02(439H)Multi-Function Digital InputTerminal S2 Function SelectionDefault: 41 (F) <31>Min: 1Max: 9F235H1-03(400H)Multi-Function Digital InputTerminal S3 Function SelectionDefault: 24Min: 0Max: 9F235H1-04(401H)Multi-Function Digital InputTerminal S4 Function SelectionDefault: 14Min: 0Max: 9F235H1-05(402H)Multi-Function Digital InputTerminal S5 Function SelectionDefault: 3 (0) <31>Min: 0Max: 9F235H1-06(403H)Multi-Function Digital InputTerminal S6 Function SelectionDefault: 4 (3) <31>Min: 0Max: 9F235H1-07(404H)Multi-Function Digital InputTerminal S7 Function SelectionDefault: 6 (4) <31>Min: 0Max: 9F235H1-08(405H)Multi-Function Digital InputTerminal S8 Function SelectionDefault: 8Min: 0Max: 9F235No.(Addr.) Name Description Setting PageAll ModesAll ModesAll ModesAll ModesAll ModesAll ModesAll ModesAll Modes