586 YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical ManualD.3 UL StandardsD.3 UL Standards UL Standards ComplianceThe UL/cUL mark applies to products in the United States and Canada. It indicates that UL has performed producttesting and evaluation, and determined that their stringent standards for product safety have been met. For a product toreceive UL certification, all components inside that product must also receive UL certification.Figure D.8Figure D.8 UL/cUL MarkThis drive is tested in accordance with UL standard UL508C and complies with UL requirements. The conditionsdescribed below must be met to maintain compliance when using this drive in combination with other equipment: Installation AreaDo not install the drive to an area greater than pollution degree 2 (UL standard). Ambient TemperatureIP00 enclosure: -10 to +50CIP20/NEMA 1, UL Type 1 enclosure: -10C to +40CIP20/IP00 finless-type enclosure: -10C to +45C Main Circuit Terminal WiringYASKAWA recommends using closed-loop crimp terminals on all drive models. UL/cUL approval requires the use ofUL Listed closed-loop crimp terminals when wiring the drive main circuit terminals on models CIMR-A2A0110 to2A0415 and 4A0058 to 4A1200. Use only the tools recommended by the terminal manufacturer for crimping.The wire gauges listed in Table D.5 and Table D.6 are YASKAWA recommendations. Refer to local codes for properwire gauge selections.Wire Gauges and Tightening TorquesTable D.5 Wire Gauge and Torque Specifications (Three-phase 200 V Class)ModelCIMR-A TerminalFor Europe and China <1> For U.S.A. <2> For Asia <3>ScrewSizeTighteningTorqueNm (lb.in.)Recomm.Wire Sizemm2ApplicableWire Sizemm2Recomm.GaugeAWG, kcmilApplicableGaugeAWG, kcmilRecomm.Wire Sizemm2ApplicableWire Sizemm22A00042A00062A0010<4>R/L1, S/L2, T/L3 2.5 2.5 to 6 14 14 to 10 2 2 to 5.5M4 1.2 to 1.5(10.6 to 13.3)U/T1, V/T2, W/T3 2.5 2.5 to 6 14 14 to 10 2 2 to 5.5–, +1, +2 – 2.5 to 6 – 14 to 10 2 2 to 5.5B1, B2 – 2.5 to 6 – 14 to 10 2 2 to 5.52.5 2.5 to 6 10 14 to 10 2 2 to 5.52A0012<4>R/L1, S/L2, T/L3 2.5 2.5 to 6 12 14 to 10 2 2 to 5.5M4 1.2 to 1.5(10.6 to 13.3)U/T1, V/T2, W/T3 2.5 2.5 to 6 14 14 to 10 2 2 to 5.5–, +1, +2 – 2.5 to 6 – 14 to 10 2 2 to 5.5B1, B2 – 2.5 to 6 – 14 to 10 2 2 to 5.52.5 2.5 to 6 10 14 to 10 3.5 2 to 5.52A0021<4>R/L1, S/L2, T/L3 4 2.5 to 6 10 12 to 10 5.5 3.5 to 5.5M4 1.2 to 1.5(10.6 to 13.3)U/T1, V/T2, W/T3 2.5 2.5 to 6 10 12 to 10 3.5 3.5 to 5.5–, +1, +2 – 4 to 6 – 12 to 10 5.5 3.5 to 5.5B1, B2 – 2.5 to 6 – 14 to 10 2 2 to 5.54 4 to 6 10 12 to 10 3.5 3.5 to 5.5