3 Maintenance3.7.3. SIS system parameters3HAC020993-001 Revision: G192© Copyright 2004-2008 ABB. All rights reserved.3.7.3. SIS system parametersGeneralThis section details the system parameters that may be set with estimated values. The valuescan be defined by the operating organization as knowledge of the robot's working conditionsare accumulated.Since the counters are to be used for purposes defined by the user, ABB cannot give anyrecommendations regarding their definitions.The figures below shows the options of parameters to be set.en0200000049Operation time limit (service level)The number of operation hours selected as service interval.E.g. by setting the value "20,000", the SIS will save this as the nominal time for activatingthe alarm, not counting the percentage described below.Operation time warningA percentage of the "Operation time limit" specified above.E.g. by setting the value "90", the SIS will alert the operator 18,000 hours after an operationtime "Reset" was made the last time.Calendar time limit (service level)The number of calendar years selected as service interval.E.g. by setting the value "2", the SIS will save this as the nominal time for activating thealarm, not counting the percentage described below.Calendar time warningA percentage of the "Calendar time limit" specified above.E.g. by setting the value "90", the SIS will alert the operator after 90% of two years, i.e. 657days after a calendar time "Reset" was made the last time.Continues on next page