CHAPTER 13 TROUBLESHOOTINGCOPYRIGHT © 2002 CANON INC. 2000 CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002 13-1836.2.2 Finisher Error CodesE500 An error has occurred in the communication between the machine and thefinisher twice continuously.Possible cause The harness to the finisher is faulty (disconnected connector, open cir-cuit). The finisher controller PCB or the DC controller PCB is faulty.Remedy1) Power switchTry turning off and then on the power switch. Is the fault cor-rected?YES : End.2) WiringIs the wiring from the finisher controller PCB to the DC control-ler PCB normal?NO : Corrected the wiring.3) Finisher controller PCB, DC controller PCBTry replacing the finisher controller PCB. Is the fault corrected?YES : End.NO : Replace the DC controller PCB.E514 The stack delivery belt does not reach home position when the stack han-dling motor (M2) is driven for a specific time (CW; if the same conditionoccurs during stack delivery, a jam will be identified).Possible cause The stack handling motor (M2) is faulty. The stack delivery home posi-tion sensor (S8) is faulty. The connector is disconnected or has an opera-tion circuit. The stack handling motor relay harness is faulty. The stackdelivery belt is faulty. The finisher controller PCB is faulty.Remedy1) Stack handling motor drive beltIs the tension of the drive belt appropriate?NO : Loosen the screw on the tension to correct the tension.2) WiringIs the wiring between the finisher controller PCB and the harnesshandling motor (M2) normal?NO : Correct the wiring.3) Sensor flagAre the sensor flag spring and the flag normal?NO : Correct the spring or the flag.