COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 5 PICK UP/FEEDING SYSTEM5-51 P3) Disengage the hook [4] of the separa-tion roller assembly, and detach theseparation roller [5].F05-901-079.1.6 Adjusting the Pressure of the Separation Roller1) Remove the right upper cover.2) Remove the upper guide [1].3) If double feeding or pickup failure oc-curs during pickup, adjust the positionof the pressure spring of the separationroller.F05-901-08• If double feeding occurs, remove themounting screw [2], and shift down themounting base [3]; then, fix it in hole Ausing a mounting screw [2].• If pickup failure occurs, remove themounting screw [2], and shift themounting base [3] up; then, fix it inhole B using a mounting screw [2].F05-901-09[1][5][4][2][3]Hole AHole BDownload Free Service Manual at http://printer1.blogspot.com