COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 3 INSTALLATION3-1 S1. Selecting the SiteThe site must satisfy the following conditions; if possible, pay a visit before the deliveryof the machine:1. The temperature must be between 75° and 32.5°C (59° and 86°F) and the humiditymust be between 5% and 85%. Avoid an area near a water faucet, water boiler, humidi-fier, or refrigerator.2. Avoid an area near a source of fire or subject to dust or ammonium gas. If the site isexposed to direct sunlight, provide a curtain.3. The level of ozone generated by the machine is not likely to affect the health of peoplearound it. Some individuals, however, may find its odor unpleasant, calling for a goodmeans of ventilation.4. Be sure that the machine’s feet will be in contact with the floor, and the machine willremain level.5. Be sure that the machine will be at least 10 cm away from any wall, and make surethere will be adequate space for machine operation.50 cm min. 60 cm min.50 cm min.10 cm min.Front coverBodyF03-100-016. Be sure that the room will be well ventilated and the machine will not be installed nearan air vent.Download Free Service Manual at http://printer1.blogspot.com