COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 3 STANDARDS AND ADJUSTMENTS3-14 T4.7 Adjusting the Pressure of the Separation Roller of theManual Feed TrayIf double feeding or pickup failure occurs during pickup, adjust the position of the pres-sure spring of the separation roller.1) Remove the right upper cover.2) Remove the upper guide [1].F03-407-01• If double feeding occurs, remove the mounting screw [2], and lower the mounting base[3]; then, tighten the mounting screw [2] in hole A.• If pickup failure occurs, remove the mounting screw [2], and raise the mounting base[3]; then, tighten the mounting screw [3] in hole B.F03-407-02[1][2][3]hole Ahole BDownload Free Service Manual at http://printer1.blogspot.com