COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS4-33 T4.1.34 E717Connector1) Is the remote diagnostic device PCB connected securely?NO: Connect it securely.Remote diagnostic device PCB, Main controller PCB2) Try replacing the remote diagnostic device PCB. Is the problemcorrected?YES: End.NO: Replace the main controller PCB.4.1.35 E719Connector1) Is the coin vendor connected securely?NO: Connect the coin vendor securely.Coin vendor, Main controller PCB3) Try connecting to a different coin vendor. Is the problem corrected?YES: End.NO: Replace the main controller PCB.4.1.36 E732Wrong operation1) Turn off and then on the main power switch. Is the problem cor-rected?YES: Check the operation once again; if normal, end the work.Connectors, Reader controller PCB2) Is the connection of the connector (J1014) on the main controllerPCB and the connector (J5004) on the reader controller PCB nor-mal? Further, is the cable between these connectors normal?NO: Correct the connectors/cable.YES: Replace the reader controller PCB.4.1.37 E733Wrong operation1) Turn off and then on the main power switch. Is the problem cor-rected?YES: Check the operation once again; if normal, end the work.Download Free Service Manual at http://printer1.blogspot.com