COPYRIGHT © 2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000CHAPTER 6 SELF DIAGNOSIS6-3 TE010Main Cause The main motor (M2) is faulty. The DC controller PCB is faulty.Mode ofDetection0000 The clock pulses do not arrive for 2 secs or more after the mainmotor drive signal (MMFG) has been generated.E012Main Cause The drum motor (M1) is faulty. The DC controller PCB is faulty.Mode ofDetection0000 The clock pulses do not arrive for 2 secs or more after the drummotor drive signal (DMFG) has been generated.E013Main Cause The waste toner feedscrew is faulty. The water toner clock sensor (MSW2)is faulty. The DC controller PCB is faulty.Mode ofDetection0000 The rotation of the waste toner feedscrew goes out of order, andthe switch (MSW2) is pressed multiple times during a specific pe-riod of time.E014Main Cause The fixing motor (M19) is faulty. The DC controller PCB is faulty.Mode ofDetection0000 The motor clock signal is detected for 2 secs or more continuouslyafter the fixing motor drive signal has been generated.E020Main Cause The hopper connector is left disconnected. The hopper motor (M9/M10) isfaulty. The toner sensor (TS1/TS2) is faulty. The DC controller PCB isfaulty.Mode ofDetection0000 During printing, the toner supply signal is '0' (absence of toner) for2 mins.Download Free Service Manual at http://printer1.blogspot.com