CHAPTER 3: IEC 61850 COMMUNICATION MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)UR FAMILY – COMMUNICATIONS GUIDE 3-1633Table 3-183: Field contact output data objects3.5.4.10 Field latching outputs (FLOut)This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,N60, T35, T60).Table 3-184: Field latching output data objects3.5.4.11 Field RTDs (FRTDs)This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,N60, T35, T60).Table 3-185: Field RTD data objectsLNName: FCOutGGIO1 LDevice inst: System UR element: Field Contact Outputsdata obj. data attribute Type FC UR Name Description R/W/CInd1Θ SPS FCO φ DOn operand value RstVal BOOLEAN ST FCO φ DOn RInd2Θ SPS Only instantiated for SSR contact outputs,i.e., OUT1 to OUT4RstVal BOOLEAN ST FCO φ IOn RInd3Θ SPS Only instantiated for SSR contact outputs,i.e., OUT1 to OUT4RstVal BOOLEAN ST FCO φ VOn RInRef1Θ ORG FCO φ Operate setting. RsetSrcRef ObjectReference SP Operate setting of FCO φ reference to the data attribute to input R/CsetSrcCB ObjectReference SP source GoCB of input if via GOOSE R/CInRef2Θ ORG FCO φ Seal-In setting. RsetSrcRef ObjectReference SP Seal-In setting of FCO φ reference to the data attribute to input R/CsetSrcCB ObjectReference SP source GoCB of input if via GOOSE R/CLNName: FLOutGGIO1 LDevice inst: System UR element: Field Latching Outputsdata obj. data attribute Type FC UR Name Description R/W/CInd1Θ SPS FLO Θ Opened operand value RstVal BOOLEAN ST FLO Θ Opened RInd2Θ SPS FLO Θ Closed operand value RstVal BOOLEAN ST FLO Θ Closed RInd3Θ SPS FLO Θ OpnDOn operand value RstVal BOOLEAN ST FLO Θ OpnDOn RInd4Θ SPS FLO Θ ClsDOn operand value RstVal BOOLEAN ST FLO Θ ClsDOn RInRef1Θ ORG FLO Θ Open setting. RsetSrcRef ObjectReference SP Open setting of FLO Θ reference to the data attribute to input R/CsetSrcCB ObjectReference SP source GoCB of input if via GOOSE R/CInRef2Θ ORG FLO Θ Close setting. RsetSrcRef ObjectReference SP Close setting of FLO Θ reference to the data attribute to input R/CsetSrcCB ObjectReference SP source GoCB of input if via GOOSE R/CLNName: FRTDsGGIO1 LDevice inst: System UR element: Field RTDs (Resistance Temperature Detectors)data obj. data attribute Type FC UR Name Description R/W/CIndΘ SPS RTDΘ Trouble On operand value RstVal BOOLEAN ST RTDΘ Trouble On RAnInΘ MV RTDΘ Temperature in degree Celsius RinstMag AnalogueValue MX RinstMag.f FLOAT32 RTDΘ Temperature Rmag AnalogueValue MX R