B-20 N60 Network Stability and Synchrophasor Measurement System GE MultilinB.4 MEMORY MAPPING APPENDIX BB350A RTD Input 27 Value -32768 to 32767 °C 1 F002 0350B RTD Input 28 Value -32768 to 32767 °C 1 F002 0350C RTD Input 29 Value -32768 to 32767 °C 1 F002 0350D RTD Input 30 Value -32768 to 32767 °C 1 F002 0350E RTD Input 31 Value -32768 to 32767 °C 1 F002 0350F RTD Input 32 Value -32768 to 32767 °C 1 F002 03510 RTD Input 33 Value -32768 to 32767 °C 1 F002 03511 RTD Input 34 Value -32768 to 32767 °C 1 F002 03512 RTD Input 35 Value -32768 to 32767 °C 1 F002 03513 RTD Input 36 Value -32768 to 32767 °C 1 F002 03514 RTD Input 37 Value -32768 to 32767 °C 1 F002 03515 RTD Input 38 Value -32768 to 32767 °C 1 F002 03516 RTD Input 39 Value -32768 to 32767 °C 1 F002 03517 RTD Input 40 Value -32768 to 32767 °C 1 F002 03518 RTD Input 41 Value -32768 to 32767 °C 1 F002 03519 RTD Input 42 Value -32768 to 32767 °C 1 F002 0351A RTD Input 43 Value -32768 to 32767 °C 1 F002 0351B RTD Input 44 Value -32768 to 32767 °C 1 F002 0351C RTD Input 45 Value -32768 to 32767 °C 1 F002 0351D RTD Input 46 Value -32768 to 32767 °C 1 F002 0351E RTD Input 47 Value -32768 to 32767 °C 1 F002 0351F RTD Input 48 Value -32768 to 32767 °C 1 F002 0Ohm Input Values (Read Only) (2 modules)3520 Ohm Inputs 1 Value 0 to 65535 Ohm 1 F001 03521 Ohm Inputs 2 Value 0 to 65535 Ohm 1 F001 0Expanded Direct Input/Output Status (Read Only)3560 Direct Device States, one per register (16 items) 0 to 1 --- 1 F155 0 (Offline)3570 Direct Input States, one per register (96 items) 0 to 1 --- 1 F108 0 (Off)Field Units (Read/Write Setting) (8 modules)3800 Field Unit 1 ID 0 to 1 --- 1 F205 "U1"3806 Field Unit 1 Function 0 to 1 --- 1 F102 0 (Disabled)3807 Field Unit 1 Type 0 to 3 --- 1 F243 0 (CC-05)3808 Field Unit 1 Serial Number 1 to1 --- 1 F205 "000000000000"380E Field Unit 1 Port 1 to 4 --- 1 F001 1380F ...Repeated for Field Unit 2381E ...Repeated for Filed Unit 3382D ...Repeated for Filed Unit 4383C ...Repeated for Filed Unit 5384B ...Repeated for Filed Unit 6385A ...Repeated for Filed Unit 73869 ...Repeated for Filed Unit 8Field Unit Process Card Ports (Read/Write Setting)3878 Field Unit 1 Process Card Port 0 to 7 --- 1 F244 6 (H1a)3879 Field Unit 2 Process Card Port 0 to 7 --- 1 F244 4 (H2a)387A Field Unit3 Process Card Port 0 to 7 --- 1 F244 2 (H3a)387B Field Unit 4 Process Card Port 0 to 7 --- 1 F244 0 (H4a)387C Field Unit 5 Process Card Port 0 to 7 --- 1 F244 7 (H1b)387D Field Unit 6 Process Card Port 0 to 7 --- 1 F244 5 (H2b)387E Field Unit 7 Process Card Port 0 to 7 --- 1 F244 3 (H3b)387F Field Unit 8 Process Card Port 0 to 7 --- 1 F244 1 (H4b)Field Unit CT VT Settings (Read/Write Setting) (6 modules)3890 Remote Phase CT x Origin 1 0 to 16 --- 1 F247 0 (None)3891 Remote Phase CT x Origin 2 0 to 16 --- 1 F247 0 (None)3892 Remote Ground CT x Origin 1 0 to 16 --- 1 F248 0 (None)Table B–10: MODBUS MEMORY MAP (Sheet 12 of 62)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT