B-54 N60 Network Stability and Synchrophasor Measurement System GE MultilinB.4 MEMORY MAPPING APPENDIX BBB24E ...Repeated for Received Analog 32IEC 61850 Configurable Report Settings (Read/Write Setting)B290 IEC 61850 Configurable Reports Dataset Items (64items)0 to 848 --- 1 F615 0 (None)IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)B500 Number of Status Indications in GGIO1 8 to 128 --- 8 F001 8B501 IEC 61850 GGIO1 Indication FlexLogic Operands (128items)--- --- 1 F300 0IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)B5A0 IEC 61850 Configurable GOOSE Function (GoEna) 0 to 1 --- 1 F102 1 (Enabled)B5A1 IEC 61850 Configurable GOOSE ID --- --- --- F209 “GOOSEOut_x_”B5C2 Configurable GOOSE Destination MAC Address --- --- --- F072 0B5C5 IEC 61850 Configurable GOOSE VLAN Transmit Priority 0 to 7 --- 1 F001 4B5C6 IEC 61850 Configurable GOOSE VLAN ID 0 to 4095 --- 1 F001 0B5C7 IEC 61850 Configurable GOOSE ETYPE APPID 0 to 16383 --- 1 F001 0B5C8 IEC 61850 Configurable GOOSE ConfRev (ConfigurationRevision)1 to 4294967295 --- 1 F003 1B5CA IEC 61850 Configurable GOOSE Retransmission Curve 0 to 3 --- 1 F611 3 (Relaxed)B5CB Configurable GOOSE Dataset Items for Transmission(64 items)0 to 1008 --- 1 F616 0 (None)B60B ...Repeated for Module 2B676 ...Repeated for Module 3B6E1 ...Repeated for Module 4B74C ...Repeated for Module 5B7B7 ...Repeated for Module 6B822 ...Repeated for Module 7B88D ...Repeated for Module 8IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)B900 Configurable GOOSE Dataset Items for Reception(32 items) 0 to 197 --- 1 F233 0 (None)B920 ...Repeated for Module 2B940 ...Repeated for Module 3B960 ...Repeated for Module 4B980 ...Repeated for Module 5B9A0 ...Repeated for Module 6B9C0 ...Repeated for Module 7B9E0 ...Repeated for Module 8BA00 ...Repeated for Module 9BA20 ...Repeated for Module 10BA40 ...Repeated for Module 11BA60 ...Repeated for Module 12BA80 ...Repeated for Module 13BAA0 ...Repeated for Module 14BAC0 ...Repeated for Module 15BAE0 ...Repeated for Module 16Contact Inputs (Read/Write Setting) (96 modules)BB00 Contact Input 1 Name --- --- --- F205 “Cont Ip 1“BB06 Contact Input 1 Events 0 to 1 --- 1 F102 0 (Disabled)BB07 Contact Input 1 Debounce Time 0 to 16 ms 0.5 F001 20BB08 ...Repeated for Contact Input 2BB10 ...Repeated for Contact Input 3BB18 ...Repeated for Contact Input 4BB20 ...Repeated for Contact Input 5BB28 ...Repeated for Contact Input 6BB30 ...Repeated for Contact Input 7BB38 ...Repeated for Contact Input 8Table B–10: MODBUS MEMORY MAP (Sheet 46 of 62)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT