B-52 N60 Network Stability and Synchrophasor Measurement System GE MultilinB.4 MEMORY MAPPING APPENDIX BBAF56 ...Repeated for IEC 61850 GGIO4 Analog Input 11AF5D ...Repeated for IEC 61850 GGIO4 Analog Input 12AF64 ...Repeated for IEC 61850 GGIO4 Analog Input 13AF6B ...Repeated for IEC 61850 GGIO4 Analog Input 14AF72 ...Repeated for IEC 61850 GGIO4 Analog Input 15AF79 ...Repeated for IEC 61850 GGIO4 Analog Input 16AF80 ...Repeated for IEC 61850 GGIO4 Analog Input 17AF87 ...Repeated for IEC 61850 GGIO4 Analog Input 18AF8E ...Repeated for IEC 61850 GGIO4 Analog Input 19AF95 ...Repeated for IEC 61850 GGIO4 Analog Input 20AF9C ...Repeated for IEC 61850 GGIO4 Analog Input 21AFA3 ...Repeated for IEC 61850 GGIO4 Analog Input 22AFAA ...Repeated for IEC 61850 GGIO4 Analog Input 23AFB1 ...Repeated for IEC 61850 GGIO4 Analog Input 24AFB8 ...Repeated for IEC 61850 GGIO4 Analog Input 25AFBF ...Repeated for IEC 61850 GGIO4 Analog Input 26AFC6 ...Repeated for IEC 61850 GGIO4 Analog Input 27AFCD ...Repeated for IEC 61850 GGIO4 Analog Input 28AFD4 ...Repeated for IEC 61850 GGIO4 Analog Input 29AFDB ...Repeated for IEC 61850 GGIO4 Analog Input 30AFE2 ...Repeated for IEC 61850 GGIO4 Analog Input 31AFE9 ...Repeated for IEC 61850 GGIO4 Analog Input 32IEC 61850 GOOSE/GSSE Configuration (Read/Write Setting)B01C Default GOOSE/GSSE Update Time 1 to 60 s 1 F001 60B01D IEC 61850 GSSE Function (GsEna) 0 to 1 --- 1 F102 1 (Enabled)B01E IEC 61850 GSSE ID --- --- --- F209 “GSSEOut”B03F IEC 61850 GOOSE Function (GoEna) 0 to 1 --- 1 F102 0 (Disabled)B040 IEC 61850 GSSE Destination MAC Address --- --- --- F072 0B043 IEC 61850 Standard GOOSE ID --- --- --- F209 “GOOSEOut”B064 IEC 61850 Standard GOOSE Destination MAC Address --- --- --- F072 0B067 IEC 61850 GOOSE VLAN Transmit Priority 0 to 7 --- 1 F001 4B068 IEC 61850 GOOSE VLAN ID 0 to 4095 --- 1 F001 0B069 IEC 61850 GOOSE ETYPE APPID 0 to 16383 --- 1 F001 0B06A Reserved (2 items) 0 to 1 --- 1 F001 0IEC 61850 Server Configuration (Read/Write Settings/Commands)B06C TCP Port Number for the IEC 61850 / MMS Protocol 1 to 65535 --- 1 F001 102B06D IEC 61850 Logical Device Name --- --- --- F213 “IEDName”B07D IEC 61850 Logical Device Instance --- --- --- F213 “LDInst”B08D IEC 61850 LPHD Location 0 to 65534 --- 1 F204 “Location”B0B5 Include Non-IEC 61850 Data 0 to 1 --- 1 F102 0 (Disabled)B06B IEC 61850 Server Data Scanning Function 0 to 1 --- 1 F102 0 (Disabled)B0B7 Reserved (9 items) 0 to 1 --- 1 F001 0IEC 61850 MMXU Deadbands (Read/Write Setting) (6 modules)B0C0 IEC 61850 MMXU TotW Deadband 1 0.001 to 100 % 0.001 F003 10000B0C2 IEC 61850 MMXU TotVAr Deadband 1 0.001 to 100 % 0.001 F003 10000B0C4 IEC 61850 MMXU TotVA Deadband 1 0.001 to 100 % 0.001 F003 10000B0C6 IEC 61850 MMXU TotPF Deadband 1 0.001 to 100 % 0.001 F003 10000B0C8 IEC 61850 MMXU Hz Deadband 1 0.001 to 100 % 0.001 F003 10000B0CA IEC 61850 MMXU PPV.phsAB Deadband 1 0.001 to 100 % 0.001 F003 10000B0CC IEC 61850 MMXU PPV.phsBC Deadband 1 0.001 to 100 % 0.001 F003 10000B0CE IEC 61850 MMXU PPV.phsCA Deadband 1 0.001 to 100 % 0.001 F003 10000B0D0 IEC 61850 MMXU PhV.phsA Deadband 1 0.001 to 100 % 0.001 F003 10000B0D2 IEC 61850 MMXU PhV.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0D4 IEC 61850 MMXU PhV.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000Table B–10: MODBUS MEMORY MAP (Sheet 44 of 62)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT