34Alarm-OutHighlight “Alarm-Out” in the Devices menu and press the button. The Alarm-Out setup screen allows youto change the settings and establish a schedule for each alarm output from the recorder. (The 4-channelmodel has only 1 Alarm Output Terminal.)Each alarm output can be given its own title byhighlighting the box under the “Title” heading andpressing the button. A virtual keyboard appearsallowing you to enter the title.Highlighting the box under the “Type” heading allows toset the alarm output.If "Type" set to "NO"(default), when alarms : [NC-GND]turns to OPEN circuit (Normally closed), [NO-GND]turns to CLOSE circuit (Normally opened). If "Type" setto "NC", when alarms : [NC-GND] turns to CLOSEcircuit (Normally opened), [NO-GND] turns to OPENcircuit (Normally closed).Figure 42 : Alarm-Out - Settings screenNote: When "Type" is set to "NC", the alarm output’s status turns to “ON” while the recorder isoff. (Refer to the Appendix – "Pin Outs" for details.)Highlighting the box beside “Dwell Time” and pressing the button allows you to set the dwell time of thealarm output. Dwell times range from 5 seconds to 30 minutes.Highlighting the “Schedule” tab causes the Schedule screen to display.You can add and edit alarm output schedules on thisscreen. Highlight the “+” and press the button toadd a schedule. Highlighting the boxes under theColumn heading and pressing the button allows youto edit the information in those boxes.The “Day” box allows you to select the days that thealarm schedule will be active. The choices are: “Sun”,“Mon”, “Tue”, “Wed”, “Thu”, “Fri”, “Sat”, “M~F”, “Hol”and “All”.The “Range” box allows you to set the time that thealarm schedule will be active in 15-minute incrementsfrom 00:00 to 24:00.Figure 43 : Alarm-Out - Schedule screenNote: Set the range as “00:00 ~ 24:00” when you want to set up the schedule for 24 hours.The “Mode” box allows you to set how the alarm reacts during the scheduled time. When set to “On”, theAlarm-Out is active during the scheduled time. When set to “Event”, the Alarm-Out is only active when thereis an Event during the scheduled time.The “Channels” box allows you to set which alarm outputs will be active. You can also select the recorder’sinternal buzzer.The “ ” box allows you to delete an alarm output schedule. You will be asked to confirm whether or not youreally wish to delete the schedule.You can save your Alarm-Out changes by highlighting “Save” and pressing the button. Selecting “Cancel”exits the screen without saving the changes.