100 • Vacon apfiff09 marineTel. +3586P2.3.9 Inching ramp ID1257This parameter defines acceleration and deceleration times when inching is active.Inching function will start the drive to reference without additional start commandregardless of control place. Inching function requires enabling from digital input beforecommand is accepted. Inching is also disabled if there is a start command active on theactive control place.Other parameters for inching:- Parameter: Inching Reference 1- Parameter: Inching Reference 2- Digital input selection: Enable Inching- Digital input selection: Inching 1- Digital input selection: Inching 2P2.3.10 Reduction of acceleration and deceleration times ID401Acceleration and deceleration times can be reduced with the input signal.Input signal level zero means ramp times set by parameters. Maximum level equals onetenth of the value set by parameter.AdjustInput [%]Ramp Time Factor100 %10 %Figure 7-4. Reducing acceleration and deceleration times7.3.1 Quick StopP2.3.11.1 Quick stop modeID1276Selects the mode of stopping the drive when quick stop is active. It is recommended to use same stop function in follower drives. It is recommended to use same ramp time in both drives0 Coast stop.1 Ramp stop.P2.3.11.2 Quick Stop Ramp time ID1256