apfiff09 marine vacon • 4724-hour support +358 (056.5 Output Signals6.5.1 Digital output signalsCode Parameter Min Default Cust ID NoteP2.5.1.1 Ready 0.1 0.1 432 Ready to RunP2.5.1.2 Run 0.1 0.1 433 RunningP2.5.1.3 Fault 0.1 0.1 434 Drive in fault stateP2.5.1.4 Inverted fault 0.1 0.1 435 Drive not in fault stateP2.5.1.5 Warning 0.1 0.1 436 Warning activeP2.5.1.6 External fault 0.1 0.1 437 External fault activeP2.5.1.7 Reference fault/warning 0.1 0.1 438 4 mA fault activeP2.5.1.8 Over temperature warning 0.1 0.1 439 Drive over temperatureactiveP2.5.1.9 Reverse 0.1 0.1 440 Output frequency < 0 HzP2.5.1.10 Unrequested direction 0.1 0.1 441 Reference <> OutputfrequencyP2.5.1.11 At speed 0.1 0.1 442 Reference = OutputfrequencyP2.5.1.12 Jogging speed 0.1 0.1 443 Jogging or preset speedcommand activeP2.5.1.13 External control place 0.1 0.1 444 IO control activeP2.5.1.14 External brake control 0.1 0.1 445 See explanations onchapter Brake ControlP2.5.1.15 External brake control, inverted 0.1 0.1 446P2.5.1.16 Output frequency limit 1supervision 0.1 0.1 447 See ID315P2.5.1.17 Output frequency limit 2supervision 0.1 0.1 448 See ID346P2.5.1.18 Reference limit supervision 0.1 0.1 449 See ID350P2.5.1.19 Temperature limit supervision 0.1 0.1 450 Drive temperaturesupervision. See ID354P2.5.1.20 Torque limit supervision 0.1 0.1 451 See ID348P2.5.1.21 Motor thermal protection 0.1 0.1 452 Thermistor fault orwarningP2.5.1.22 Analogue input supervisionlimit 0.1 0.1 463 See ID356P2.5.1.23 Motor regulator activation 0.1 0.1 454 One of limit controller isactiveP2.5.1.24 Fieldbus digital input 1 0.1 0.1 455 FB CW B11P2.5.1.25 FB Dig 1 Parameter ID0 ID0 891 Select parameter tocontrolP2.5.1.26 Fieldbus digital input 2 0.1 0.1 456 FB CW B12P2.5.1.27 FB Dig 2 Parameter ID0 ID0 892 Select parameter tocontrolP2.5.1.28 Fieldbus digital input 3 0.1 0.1 457 FB CW B13P2.5.1.29 FB Dig 3 Parameter ID0 ID0 893 Select parameter tocontrolP2.5.1.30 Fieldbus digital input 4 0.1 0.1 169 FB CW B14P2.5.1.31 FB Dig 4 Parameter ID0 ID0 894 Select parameter tocontrolP2.5.1.32 Fieldbus digital input 5 0.1 0.1 170 FB CW B15P2.5.1.33 FB Dig 5 Parameter ID0 ID0 895 Select parameter tocontrolP2.5.1.34 Safe Disable Active 0.1 0.1 756