apfiff09 marine vacon • 3524-hour support +358 (055.2.5 Frequency ChainV1.28.1 Frequency Reference 1Hz 1126Frequency reference before speed share. Speed Share is used also for referencedirection control.V1.28.2 Frequency Reference 2Hz 1126Frequency reference after speed share and reference adjust but beforeinterpolator.V1.28.3 Frequency ReferenceHz 25Frequency reference after interpolator but before second order filtering.V1.28.4 Frequency Reference Actual Hz 1128Frequency reference for ramp control.V1.28.5 Frequency Ramp Out Hz1129Ramp control output.V1.28.6 Frequency Reference Final Hz 1131Final reference to speed controller. After ramp generator and after Speed Stepfunction, used for closed loop speed tuning when used together with Encoder 1frequency.V1.28.7 Encoder 1 Frequency Hz1164Encoder frequency, monitored directly from encoder.5.2.6 Torque ChainV1.29.1 Torque reference % ID 18Torque reference value before load share.V1.29.2 Torque Reference 3 %1144Torque reference after load share. But before torque step.V1.29.3 Torque Ref Final%1145Final torque reference in torque reference chain, before accelerationcompensation and speed controller output.V1.29.4 Speed Control Out %1134Closed Loop speed controller output.V1.29.5 Torque Reference Actual % 1180Final torque reference from speed control and torque control. Also includestorque step and acceleration compensation factors.