316 APPENDIX F: REPLACING AND INSTALLING CACHE STORAGE DEVICES9 Close the front panel of the Webcache.10 Return the cache storage device to 3Com.For further information about returning a failed cache storage device to3Com, enter the following URL into your Web browser:http://knowledgebase.3com.com/division/publisher.asp?id=2.0.77094716.3290900(correct at time of publication)Adding a New CacheStorage DeviceYou can use a new cache storage device supplied by 3Com to replace thefailed device.To add a cache storage device to the Webcache 3000:1 If you have mounted the Webcache in a rack using the suppliedrack-mounting kit, you must slide the Webcache forward byapproximately 1 inch, in order to fully open the front panel.2 Open the front panel of the Webcache, as shown in Figure 37 onpage 315.3 The new cache storage device is mounted in a tray. Insert the tray intobay 1 or 2 in the Webcache and push it forwards firmly until it stops.4 Push in the arms on the front of the tray to click them into place.5 Close the front panel of the Webcache.6 Log in to the Web interface.7 Click Device on the Toolbar.8 Select System > Storage > Add Disk in the Navigation Tree. The AddCache Storage screen is displayed.You can also open this screen by clicking the cache storage device thatyou want to remove on the Device Mimic and selecting Add Storage fromthe pop-up menu. For further information, see “Device Mimic” onpage 96.9 Select the cache storage device that you want to add from the Select theCache Storage Device list. Click Add.10 The Webcache automatically starts preparing the new cache storagedevice for use. The Cache Storage Status LED on the front panel changesto Green Flashing whilst the device is being prepared and then to Greenwhen it is in use. For further information about LEDs, see “LEDs” onpage 61.dua1611-5aaa04.book Page 316 Friday, November 29, 2002 8:56 PM