Appendix A: WPIM-SY ConfigurationA-6Local Management User’s GuideFRAME RELAY CONFIGURATIONThis section provides instructions for connecting the WPIM-SY to a DDS (Digital Data System)circuit in a Frame Relay environment. Refer back to Figure A-3 for the configuration.The line configuration information shown in Table A-1 must be supplied by the service provider.WPIM-SY Physical ConfigurationBegin the WPIM-SY Frame Relay configuration by accessing the WAN Configuration screenthrough Local Management. Proceed with the following steps:1. Use the arrow keys to highlight the [WPIM] field at the bottom of the screen. Press theSPACEBAR to select the WPIM being configured, then press ENTER.2. Use the arrow keys to highlight Mgr Type. Press the SPACEBAR to set the Mgr Type toFR PtoMP (Frame Relay Point to Multipoint) or FR PtoP (Frame Relay Point to Point), thenpress ENTER. These are the two settings for Frame Relay. Frame Relay Point to Point has oneInterface per DLCI assigned when DLCIs are created by the Service Provider. In Frame RelayPoint to Multipoint, there is one interface to multiple DLCI’S, and the DLCIs are dynamicallylearned. Backup can only be run on FR PtoP, not FR PtoMP.3. Use the arrow keys to highlight SYNC PORT TYPE. Press the SPACEBAR to set the SyncPort Type to V.35, RS422, RS232, or X.21.4. Use the arrow keys to highlight FORCE CTS True. Press the SPACEBAR to set to NO.5. Use the arrow keys to highlight FORCE DSR True. Press the SPACEBAR to set to NO.6. Use the arrow keys to highlight FORCE RTS True. Press the SPACEBAR to set to ENABLE.7. Use the arrow keys to highlight FORCE DTR True. Press the SPACEBAR to set toENABLE.Table A-2 Telco Configuration InformationConfiguration Information Required By User Configuration Information Supplied By ServiceProviderClock Source Telco provided or no clock sourceCircuit Speed 64K, V.35, RS-422, RS-232, etc.