7CMC Event MessagesCMC8501Message Chassis Group Leader has synchronized this members configuration.DetailedDescriptionMulti Chassis Management feature on CMC allows for pushing the lead chassis configurationdata to its members. This message appears in the members log when the configuration data issuccessfully synchronized with the Chassis group leaders configuration data.RecommendedResponse ActionNo response action required.Category ConfigurationSubCategory CMC = Chassis Management ControllerSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSECMC8502Message Unable to access the IPv6 information of the server.DetailedDescriptionCMC is unable to access the specified servers IPv6 information. Unable to display the specifiedservers Launch iDRAC link on the CMC Web interface.RecommendedResponse ActionEnable IPv6 for the specified server using the CMC command line or CMC Web GUI interface,so that the link to launch iDRAC is displayed on the CMC Web interface. For the command lineoptions or navigation for Web intereface, see the Trobleshooting section in the CMC UsersGuide.Category System HealthSubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message No LCD message display defined.105