Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR22Message SMART warning temperature forarg1Arguments •arg1 = PD NameDetailedDescriptionA disk has reached an unacceptable temperature and received a SMART alert (predictivefailure). The disk is likely to fail in the near future.RecommendedResponse ActionDo the following: 1) Determine why the physical disk reached an unacceptable temperature.For example, a fan failure, incorrect thermostat settings, or the room temperature may be toohot or cold. 2) Verify that the fans in the server or enclosure are working. 3) If the physical diskis in an enclosure, check the thermostat settings and examine whether the enclosure islocated near a heat source. Verify the enclosure has enough ventilation and that the roomtemperature is not too hot. Refer to the enclosure documentation for more diagnosticinformation. 4) If you cannot identify why the disk has reached an unacceptable temperature,then replace the disk. If the physical disk is a member of a non-redundant virtual disk, thenback up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.Category StorageSubCategory PDR = Physical DiskSeverity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR23Message SMART warning degraded forarg1Arguments •arg1 = PD Name438