RecommendedResponse ActionCheck the event log for power supply failures. Review system configuration and powerconsumption.Category System HealthSubCategory RDU = RedundancySeverity Severity 1 (Critical)Trap/EventID 2473LCD Message Lost PSU redundancy. Check PSU cablesInitial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSERDU0013Message Power supply redundancy is degraded.DetailedDescriptionThe current power operational mode is non-redundant because of a power supply exception, apower supply inventory change, or a system power inventory change. The system waspreviously operating in a power redundant mode.RecommendedResponse ActionCheck the event log for power supply failures. Review system configuration and powerconsumption.Category System HealthSubCategory RDU = RedundancySeverity Severity 2 (Warning)Trap/EventID 2474LCD Message PSU redundancy degraded. Check PSU cablesInitial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSERDU0014Message The power supplies are not redundant.DetailedDescriptionThe current power supply configuration does not meet the platform requirements to enableredundancy. If a power supply fails the system may shut down.RecommendedResponse ActionIf unintended, review system configuration and power consumption and install power suppliesaccordingly. Check power supply status for failures.Category System Health640