RecommendedResponse Action1) Turn system off and remove input power for one minute. Re-apply input power and turnsystem on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contacttechnical support. Refer to the product documentation to choose a convenient contact method.Category System HealthSubCategory CPU = ProcessorSeverity Severity 1 (Critical)Trap/EventID FALSELCD Message Power input for CPU voltage regulator module is outside of range. Reseat moduleInitial Default. FALSEFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSECPU0805Message The power input for CPUarg1voltage regulator module is outside of range, but it is attached tothe system.Arguments •arg1 = numberDetailedDescriptionSystem performance may be degraded or the system may fail to operate.RecommendedResponse Action1) Turn system off and remove input power for one minute. Re-apply input power and turnsystem on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contacttechnical support. Refer to the product documentation to choose a convenient contact method.Category System HealthSubCategory CPU = ProcessorSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. FALSEFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSECPU0806Message CPUarg1voltage regulator module is incorrectly configure.151