RecommendedResponse ActionDo the following: 1) Remove the server identified in the message. 2) Restart the CMC and waitfor the CMC to complete the start up process. 3) Reinsert the server identified in the message.If the problem persists, contact your service provider.Category System HealthSubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)Trap/EventID 2545LCD Message No LCD message display defined.Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSECMC8519Message The LOM riser FRU for slotarg1FRU IDarg2is not functioning.Arguments •arg1 = slot number•arg2 = fru idDetailedDescriptionFRU of the LOM riser specified in the message is not functioning or CMC is unable to read it.RecommendedResponse ActionDo the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) ResetCMC and wait for a few minutes. If the issue persists, contact your service provider.Category System HealthSubCategory CMC = Chassis Management ControllerSeverity Severity 1 (Critical)Trap/EventID 2545LCD Message No LCD message display defined.Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSECMC8520Message The FRU on serverarg1is not functioning.Arguments •arg1 = slot number114