FilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEVDR51Message The consistency check process made corrections and completed onarg1.Arguments •arg1 = virtual diskDetailedDescriptionThe consistency check completed on the virtual disk after making corrections.RecommendedResponse ActionNo response action is required.Category StorageSubCategory VDR = Virtual DiskSeverity Severity 3 (Informational)Trap/EventID 4355LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEVDR52Message The consistency check found inconsistent parity data onarg1.Arguments •arg1 = virtual diskDetailedDescriptionThe data on physical disk members of the virtual disk does not match. Redundancy may be lost.RecommendedResponse ActionRerun the consistency check task. If you receive this message again, verify the health of thephysical disks included in the virtual disk. See the storage hardware documentation for moreinformation. Review messages for significant messages related to the physical disks. If aphysical disk has a problem, replace it and restore from a backup copy. Contact technicalsupport if the issue persists.Category StorageSubCategory VDR = Virtual DiskSeverity Severity 2 (Warning)884