Severity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSETMP8502Message Able to read planar board temperature sensors. Cooling set for normal chassis operation.DetailedDescriptionThe system has recovered from being unable to read planar board or control paneltemperature sensors.RecommendedResponse ActionNo response action required.Category AuditSubCategory TMP = TemperatureSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSETMP1000Messagearg1exceeded the maximum warning threshold.Arguments •arg1 = tempsensor nameDetailedDescriptionThe enclosure is too hot. A variety of factors can cause the excessive temperature. Forexample, a fan may have failed, the thermostat may be set too high, or the room temperaturemay be too hot.RecommendedResponse ActionCheck for factors that may cause overheating. For example, verify that the enclosure fan isworking. You should check the thermostat settings and examine whether the enclosure islocated near a heat source. Make sure the enclosure has enough ventilation and that the roomtemperature is not too hot. Refer to the enclosure documentation for more diagnosticinformation.820