RecommendedResponse ActionMake sure the user name is valid. If communication with iDRAC is not successful, reset theiDRAC. Retry the operation after a few minutes.Category AuditSubCategory SWC = Software ConfigSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWC8528Message Chassis Management Controller is unable to update the iDRAC root password.DetailedDescriptionThe Chassis Management Controller is unable to update the IDRAC "root" user password. Thiscan happen if the communction to the iDRAC from CMC is non-functional or if the passwordentered is not valid.RecommendedResponse ActionMake sure the password is valid. If communications with the iDRAC is not functioning, resetthe iDRAC and retry the operation after a few minutes. Run the RACADM command "racadmping server- " to check the communications. If the communications are notfunctional, restart the iDRAC by performing a Virtual Reseat of the server using the RACADMcommand "racadm racreset -m server-".Category AuditSubCategory SWC = Software ConfigSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSESWC8529Message Chassis Management Controller unable to enable the iDRAC root user.DetailedDescriptionThe Chassis Management Controller is unable to enable the iDRAC root user. This can happenif the communction to the iDRAC from CMC is non-functional or iDRAC is rebooting772