Category StorageSubCategory PDR = Physical DiskSeverity Severity 2 (Warning)Trap/EventID 4346LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR33Message A dedicated hot spare has been removed.arg1Arguments •arg1 = PD NameDetailedDescriptionThe controller cannot to communicate with a disk that is assigned as a global hot spare. Thedisk either failed or was removed. There may also be a bad or loose cable.RecommendedResponse ActionVerify that the disk is healthy and installed. Check the cables. Refer to the productdocumentation and see the Cables Attached Correctly section for more information onchecking the cables. If necessary, replace the disk and reassign the global hot spare.Category StorageSubCategory PDR = Physical DiskSeverity Severity 3 (Informational)Trap/EventID 4347LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEPDR34Message A dedicated hot spare has been automatically unassigned.arg1Arguments •arg1 = PD NameDetailedDescriptionThe hot spare is no longer required because the virtual disk it was assigned to has beendeleted.444