BAT1003Message The battery onarg1learn cycle has completed.Arguments •arg1 = Controller nameDetailedDescriptionThis alert is provided for informational purposes.RecommendedResponse ActionNo response action is required.Category StorageSubCategory BAT = Battery EventSeverity Severity 3 (Informational)Trap/EventID 4275LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSEBAT1004Message The battery onarg1learn cycle has timed out.Arguments •arg1 = Controller nameDetailedDescriptionThe controller battery must be fully charged before the learn cycle can begin. The battery maybe unable to maintain a full charge causing the learn cycle to timeout. In addition, the batterymust be able to maintain cached data for a specified period of time in the event of a powerloss. For example, some batteries maintain cached data for 24 hours. If the battery is unable tomaintain cached data for the required period of time, then the Learn cycle will timeout.RecommendedResponse ActionReplace the battery pack. The battery is unable to maintain a full charge.Category StorageSubCategory BAT = Battery EventSeverity Severity 2 (Warning)Trap/EventID 4274LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System Log73