DetailedDescriptionThe Virtual Reseat initiated on the Sleeve identified in the message successfully turned off theSleeve. However, the Sleeve did not turn on successfully. A Virtual Reseat is the same asremoving and inserting a Sleeve.RecommendedResponse ActionRetry the Virtual Reseat operation on the Sleeve identified in the message. If the issue persists,manually remove and reinsert the Sleeve in the chassis.Category AuditSubCategory PWR = Power UsageSeverity Severity 2 (Warning)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSEPWR8577Message A Virtual Reseat operation is initiated on Sleevearg1.Arguments •arg1 = sleeve numberDetailedDescriptionA Virtual Reseat operation is initiated on the Sleeve identified in the message. A Virtual Reseatis the same as removing and inserting a Sleeve.RecommendedResponse ActionNo response action is required.Category AuditSubCategory PWR = Power UsageSeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSEPWR8578Message Chassis Management Controller is unable to turn on the iDRAC on server-arg1because powerrequired is less than available power.585