Severity Severity 1 (Critical)Trap/EventID 4329LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSECTL48Message A foreign configuration was detected onarg1.Arguments •arg1 = controller nameDetailedDescriptionThe controller has physical disks that were moved from another controller or have beenremoved and replaced on the current configuration. These physical disks contain virtual disksthat were created on the current or other controller. See the storage hardware documentationfor Import Foreign Configuration and Clear Foreign Configuration for more information. Foreignconfiguration is seen when a controller is replaced.RecommendedResponse ActionImport or clear the detected foreign configuration using a configuration tool or utility.Category StorageSubCategory CTL = Storage ContrSeverity Severity 3 (Informational)Trap/EventID 4331LCD Message No LCD message display defined.Initial Default. SNMP Alert;#LCD;#Remote System LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetTRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSECTL49Message The NVRAM has corrupted data onarg1.Arguments •arg1 = Controller nameDetailedDescriptionThe NVRAM has corrupted data. This may occur after a power surge, a battery failure, or forother reasons. The controller is reinitializing the NVRAM.185