RecommendedResponse ActionCheck the status of the standby CMC and make sure the firmware version matches the primaryCMC. Then reseat the CMC and retry the operation. If the issue persists, contact your serviceprovider.Category AuditSubCategory RDU = RedundancySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSERDU8509Message CMCarg1: cannot failover, chassis is in non-redundant stateArguments •arg1 = slot numberDetailedDescriptionFor failover to occur, the standby CMC needs to be present, at the same version as the primaryand healthy. During failover, the active CMC resets and the standby CMC becomes active. Thismessage is logged when the standby CMC is absent, unhealthy or at a different firmwareversion.RecommendedResponse ActionCheck the status of the standby CMC and make sure the firmware version matches the primaryCMC. Then reseat the CMC and retry the operation. If the issue persists, contact your serviceprovider.Category AuditSubCategory RDU = RedundancySeverity Severity 3 (Informational)Trap/EventID FALSELCD Message No LCD message display defined.Initial Default. LC LogFilterVisibility IPMI Alert SNMPAlert EmailAlert LC Log LCD Power Off PowerCycle ResetFALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSERDU8510Message CMCarg1: cannot failover, CMC firmware versions are different628