Eaton Power Xpert 9395C UPS Installation and Operation Manual 164000821—Rev 06 139CChhaapptteerr 88 CCoommmmuunniiccaattiioonnThis chapter describes the communication features of the Eaton Power Xpert 9395C UPS system and providesinformation about connecting hardware. For terminal wiring information, see paragraph3.2.5 UPS System Interface Wiring Preparation and paragraph 4.7 Installing Interface Connections. For locationof the customer interface panels and terminals, see Figure 27 and Figure 31 through Figure 34.88..11 XX--SSlloott CCaarrddssThe Eaton 9395C UPS system has four standard, factory-installed X-Slot communication bays. See Figure 31for bay locations. The UPS is compatible with the following X-Slot cards (see Figure 105):• Power Xpert® Gateway Card - provides a data gateway from the UPS to the Power Xpert software;provides remote monitoring through a Web browser interface, e-mail, and a network management systemusing SNMP; connects to a twisted-pair Ethernet (10/100BaseT) network. Modbus TCP support providesdirect integration of the UPS parameters to a Building Management System (BMS). It has a built-inswitching hub that allows one additional network device to be connected to the network without therequirement of an additional network drop.• Modbus Card - provides direct integration of UPS information (meters and status) to a BuildingManagement System (BMS) using the Modbus RTU protocol.• Relay Interface Card (AS/400) - has isolated dry contact (Form-C) relay outputs for UPS status: Utilityfailure, Low battery, UPS alarm/OK, or On bypass when interfacing with IBM AS/400 computers, otherrelay connected computers, and industrial applications.• Industrial Relay Card (IRC) - indicates the operating status of the UPS system using the customer'smonitoring equipment. The IRC uses four isolated normally-open or normally-closed dry relay contacts toindicate the UPS status. Online, Bypass, Battery, and Alarm modes can be monitored.• Powerware Hot Sync CAN Bridge Card - provides connectivity for operational mode control and meteringof a parallel system at any UPS in the system. In addition, this card can be used to connect optional systemmonitoring devices, such as a Remote Monitor Panel II (RMP II), a Relay Interface Module II (RIM II), or aSupervisory Contact Module II (SCM II) to the UPS.LAN drops for use with X-Slot connectivity cards must be provided by facility planners or the customer.For installation and setup of an X-Slot card, contact an Eaton service representative (see para. 1.7 Getting Help).Refer to the manual supplied with the X-Slot card for user instructions.Figure 105. Optional X-Slot CardsRelay Interface CardModbus Card Hot Sync CAN BridgeCardIndustrial Relay CardPower Xpert Gateway Card88..22 PPrreeddiiccttPPuullsseeThe Eaton 9395C UPS supports Eaton's. PredictPulse Remote Monitoring and Management Service is asubscription monitoring and management service that collects and analyzes data from connected power