Eaton Power Xpert 9395C UPS Installation and Operation Manual 164000821—Rev 06 3• X-Slot® Communication Bays. Four communication bays are standard equipment. One to four optional X-Slot® connectivity cards can be installed in the UPS module at any time. X-Slot cards are quickly installed atthe front of the UPS and are hot-pluggable. See Chapter 8 Communication for additional information.11..11..44 AAddvvaanncceedd BBaatttteerryy MMaannaaggeemmeennttA three-stage charging system increases battery service life by optimizing recharge time, and protects batteriesfrom damage due to high current charging and inverter ripple currents. Charging at high currents can overheatand damage batteries.11..11..55 PPoowweerr MMaannaaggeemmeenntt SSooffttwwaarreeEaton’s Intelligent Power® Software solution, based on Web2.0 technology, includes two applications:Intelligent Power® Manager™ for UPS management and monitoring, and Intelligent Power® Protector™, whichallows graceful shutdown of operating systems. See Chapter 8 Communication for additional information.11..22 OOppttiioonnss aanndd AAcccceessssoorriieessContact an Eaton sales representative for information about the following options.11..22..11 IInntteeggrraatteedd BBaatttteerryy CCaabbiinneettssBattery backup protection can be provided by equipping the UPS system with Eaton 9395C battery cabinetscontaining sealed lead-acid, maintenance-free batteries. The cabinets are designed for standalone installationand may be installed adjacent to the UPS or in a separate location. The recommended installation location foradjacent battery cabinets is on the right side of the UPS cabinet to allow for future expansion using an externalmodule.Consult the Eaton® Power Xpert® 9395C Integrated Battery Cabinet (Models 1085 and 1085HR) InstallationManual (TBD) for specifics on battery cabinet usage with the 9395C.11..22..22 SSyynncc CCoonnttrroollAn optional Eaton 9395C Sync Control maintains the critical load outputs of two separate single module 9395CUPS systems in synchronization. This option facilitates the uninterrupted transfer of the load from one load busto another by means of transfer switches. The Sync Control is housed in a wall-mounted panel that can belocated between the UPS units for easy wiring.11..22..33 SSiinnggllee--FFeeeedd KKiittAn optional kit is available for converting the dual-feed rectifier and bypass inputs to a single-feed configuration.The kit consists of jumpers and bus bar extensions for each phase, and the hardware required for installation.11..22..44 DDiissttrriibbuutteedd BByyppaassss SSyysstteemmThe 9395C is based on UPS redundancy. Each UPS contains a UPM.A distributed bypass UPS system with two to five UPSs can be installed to provide a capacity and/or redundantsystem. This load sharing system provides more capacity than a single UPS, and can provide backup,depending on the load and configuration. A Powerware Hot Sync Controller Area Network (CAN) Bridge Cardprovides connectivity and operational mode control. The distributed bypass system consists of two to fiveUPSs each with a parallel CAN card, and a customer-supplied tie cabinet or load distribution panel to act as a tiepoint.The tie cabinet is provided by the customer and must contain Module Output Breakers (MOBs) with dualauxiliary contacts for control of the system.11..22..55 CCoonnttiinnuuoouuss SSttaattiicc SSwwiittcchhA continuous static switch is used to provide transfer of the load from the inverter to the bypass source in theevent the inverter become unavailable.Introduction