ServicerequestnumberSRNsourceFailingFunctionCode Description and action651-734 G 292 Intermediate or system bus data parity error.651-735 G 292 Intermediate or system bus time-out error.651-736 G 292 Intermediate or system bus time-out error.651-740 G 2D3 Note: Ensure that the system IPLROS and service processor are at thelatest firmware level before removing any parts from the system.651-741 G 2D3 Service processor error accessing special registers.651-742 G 2D3 Service processor reports unknown communication error.651-743 G 2D5 Service processor error accessing Vital Product Data EEPROM.651-745 G 2D9 Service processor error accessing power controller.651-746 G 2D4 Service processor error accessing fan sensor.651-747 G 2D5 Service processor error accessing thermal sensor.651-748 G 2E2 Service processor error accessing voltage sensor.651-750 G 2D4 Service processor detected NVRAM error.651-751 G 2D4 Service processor error accessing real-time clock/time-of-day clock.651-752 G 2D4 Service processor error accessing JTAG/COP controller/hardware.651-753 G 1512D4Service processor detects loss of voltage from the time-of-day clock backupbattery.651-770 G 292 Intermediate or system bus address parity error.651-771 G 292 Intermediate or system bus data parity error.651-772 G 292 Intermediate or system bus time-out error.651-773 G 227 Intermediate or system bus data parity error.651-780 G 2C7214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-781 G 2C7214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-784 G 302214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-785 G 303214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-786 G 304214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-789 G 2CD214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-78A G 2CE214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-78B G 2CC214Uncorrectable memory error. Action: Use Chapter 4, “Problemdetermination procedures for AIX and Linux,” on page 21.651-809 G Power fault warning due to unspecified cause. Action: Use Chapter 4,“Problem determination procedures for AIX and Linux,” on page 21.651-810 G 2E2 Over-voltage condition was detected. Action: Shut the system down and dothe following before replacing any FRUs:1. Visually inspect the power cables and reseat the connectors.2. Run the following command diag -Avd sysplanar0. When the ResourceRepair Action menu displays, select sysplanar0.Chapter 10. Symptom-to-FRU index 115