ServicerequestnumberSRNsource Description FRU/actionA15-24x G Power Fault specifically due to internalbattery failure. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A15-50x G Recoverable errors on resource indicatea trend toward an unrecoverable error.However, the resource could not bedeconfigured and is still in use. Thesystem is operating with the potential foran unrecoverable error.1. If repair is not immediately available, rebootand the resource will be deconfigured;operations can continue in a degraded mode.2. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.3. If no entry is found, replace the system board.A1D-00x G A non-critical error has been detected.Error log analysis indicates an errordetected by the Service Processor, butthe failure could not be isolated.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-02x G A non-critical error has been detected, anI/O (I2C) general bus error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-04x G A non-critical error has been detected, aninternal service processor memory error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-05x G A non-critical error has been detected, aservice processor error accessing specialregisters.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-06x G A non-critical error has been detected, aservice processor reports unknowncommunication error.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.138 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide