ServicerequestnumberSRNsource Description FRU/actionA1D-21x G A non-critical error has been detected, aservice processor detected error withtime-of-day clock backup battery.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-23x G A non-critical error has been detected:Loss of heart beat from ServiceProcessor.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-24x G A non-critical error has been detected, aservice processor detected a surveillancetime-out.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-29x G A non-critical error has been detected, aservice process error accessing powercontrol network.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-30x G A non-critical error has been detected:Non-supported hardware. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-31x G A non-critical error has been detected:Error detected while handling anattention/interrupt from the systemhardware.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-34x G A non-critical error has been detected:Wire Test Error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A1D-35x G A non-critical error has been detected:Mainstore or Cache IPL Diagnostic Error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.140 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide