ServicerequestnumberSRNsource Description FRU/actionA05-10x G System shutdown due to FRU that hasfailed. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A05-14x G System shutdown due to power fault withan unspecified cause. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A05-19x G System shutdown due to Fan failure. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A05-21x G System shutdown due to Overtemperature condition. 1. Verify that:a. The room ambient temperature is withinthe system operating environment.b. There is unrestricted air flow around thesystem.c. All system covers are closed.d. There are no fan failures2. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.3. If no entry is found, replace the system board.A05-22x G System shutdown due to overtemperature and fan failure. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A05-24x G Power Fault specifically due to internalbattery failure. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A0D-00x G Error log analysis indicates an errordetected by the Service Processor, butthe failure could not be isolated.1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.Chapter 10. Symptom-to-FRU index 127