ServicerequestnumberSRNsource Description FRU/actionA12-04x G A non-critical error has been detected, amemory control subsystem internal error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-05x G A non-critical error has been detected, amemory address error (invalid address oraccess attempt).1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-06x G A non-critical error has been detected, amemory data error (bad data going tomemory).1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-07x G A non-critical error has been detected, amemory bus/switch internal error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-08x G A non-critical error has been detected, amemory time-out error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-09x G A non-critical error has been detected, asystem bus parity error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-10x G A non-critical error has been detected, asystem bus time-out error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.A12-11x G A non-critical error has been detected, asystem bus protocol/transfer error. 1. Check the BladeCenter management moduleevent log; if an error was recorded by thesystem or if a checkpoint code is displayed onthe console, see Chapter 10,“Symptom-to-FRU index,” on page 93.2. If no entry is found, replace the system board.132 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide