ServicerequestnumberSRNsourceFailingFunctionCode Description and action887-304 D 887 Coprocessor internal test failed.887-305 D 887 Internal loopback test failed.887-306 D 887 Internal loopback test failed.887-307 D 887 External loopback test failed.887-319 D 887 Software device driver indicates a hardware failure.887-400 D 887 Fuse test failed.887-401 D 887 Circuit breaker for Ethernet test failed.887-402 D B09887 Ethernet 10 Base-2 transceiver test failed.887-403 D B08 887 Ethernet 10 Base-T transceiver test failed.887-405 F 887 Ethernet- network Rerun diagnostics in advanced mode for accurateproblem determination.254E-201 D 254E 221 Adapter configuration error.254E-601 G 254 Error log analysis indicates adapter failure.254E-602 G 254 Error log analysis indicates an error attention condition.254E-603 G 254 Error log analysis indicates that the microcode could not be loaded on theadapter.254E-604 G 254 Error log analysis indicates a permanent adapter failure.254E-605 G 254 Error log analysis indicates permanent adapter failure is reported on theother port of this adapter.254E-606 G 254 Error log analysis indicates adapter failure.254E-701 G 254E 221 Error log analysis indicates permanent adapter failure.254E-702 G 254E 221 Error log analysis indicates permanent adapter failure is reported on theother port of this adapter.2567 USB integrated system planar.25A0 G 2631 Configuring I/O planar control logic for IDE bus devices; see “FFC table” onpage 142, FFC 2631.25C4 Broadcom adapter2631 2631 IDE controller - system planar2640-114 D 2640 IDE disk diagnostic failure2640-115 D 2640 2631 IDE disk error on open or configuring device system planar - IDE controller2640-121 D 2640 Physical volume hardware error.2640-131 G 2640 Smart status threshold exceeded.2640-132 G 2640 Command timeouts threshold exceeded.2640-133 G 2640 Command timeout with error condition.2640-134 G 2640 Hardware command or DMA failure.2640-135 G 2640 IDE DMA error with no error status.2640-136 G 2640 2631 Timeout waiting for controller or drive with no busy status.25C4-201 D 25C4 Configuration error. Use the problem determination procedure.25C4-701 G 25C4 Permanent adapter failure. Use the problem determination procedure.25C4-601 G 25C4 Download firmware error. Use the problem determination procedure.25C4-602 G 25C4 EEPROM read error. Use the problem determination procedure.120 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide