215-801-000 Optical Drive Test AbortedExplanation: Optical Drive Test Aborted. Unable to communicate with driver.Severity: WarningServiceable: YesRecoverable: NoAutomatically notify Support: NoUser response: Complete the following steps:1. Make sure that the DSA Diagnostic code is at the latest level.2. Run the test again.3. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable ifdamage is present.4. Run the test again.5. Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSADiagnostic Event Log within the Firmware/VPD section for this component.6. Run the test again.Related Links:v IBM Support Websitev Latest level of DSAv Latest level of BMC/IMM215-802-000 Optical Drive Test AbortedExplanation: Optical Drive Test Aborted. A read error was encountered.Severity: WarningServiceable: YesRecoverable: NoAutomatically notify Support: NoUser response: Complete the following steps:1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.2. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable ifdamage is present.3. Run the test again.4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for thenext corrective action.Related Links:v IBM Support Websitev Latest level of DSAv Latest level of BMC/IMM215-801-000 • 215-802-000344 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide