30. 5. Remove memory card identified and check for connector pin damage on memory card and CPU memorycard slot.31. a) Replace affected commodity if damage is found.32. 6. Swap the memory card in the slot identified, with a memory card from another slot with the sameconfiguration of DIMMs (size, type, number)33. 7. Restart the server and see if problem still identifies the same memory card slot.34. a) If problem remains with original slot, replace the I/O board assembly.35. b) If problem occurs in slot where original memory card was moved to, replace the memory card.80070608-1404ffff Sensor [SensorElementName] has transitioned to non-recoverable.Explanation: A system power fault has occurred.May also be shown as 800706081404ffff or 0x800706081404ffffSeverity: ErrorAlert Category: CriticalServiceable: NoCIM Information: Prefix: PLAT and ID: 0530SNMP Trap ID: 4Automatically notify Support: NoUser response:1. Critical: Do Not attempt to power the system on, or AC cycle. Do so only when instructed to in the followingsteps.2. 1. Using the IMM web interface, determine the version of FPGA installed and capture an IMM log for supportreference.3. Perform the following actions for the FPGA version installed.4. [FPGA versions lower than 4.00]5. 2. Remove AC power.6. 3. Remove memory card identified and check for connector pin damage on memory card and CPU memorycard slot.7. a) Replace affected commodity if damage is found.8. 4. Swap the memory card in the slot identified, with a memory card from another slot with the sameconfiguration of DIMMs (size, type, number)9. 5. Restart the server and see if problem still identifies the same memory card slot.10. a) If problem remains with original slot, replace the I/O board assembly.11. b) If problem occurs in slot where original memory card was moved to, replace the memory card.12. [FPGA versions 4.00 and 4.01]13. 2. If local, pull out the Operator Information Panel, observe and make note of what is being displayed on theCheckpoint display for support reference.14. 3. Using the IMM web interface, capture a 'Service Data' file if available (note:) for support reference.15. 4. Remove AC power.16. 5. Remove memory card identified and check for connector pin damage on memory card and CPU memorycard slot.17. a) Replace affected commodity if damage is found.18. 6. Swap the memory card in the slot identified, with a memory card from another slot with the sameconfiguration of DIMMs (size, type, number)19. 7. Restart the server and see if problem still identifies the same memory card slot.20. a) If problem remains with original slot, replace the I/O board assembly.21. b) If problem occurs in slot where original memory card was moved to, replace the memory card.22. [FPGA version 5.01]80070608-1404ffff416 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide